​​Bruker micrOTOF-Q II Quadrupole Time-of-Flight Mass Spectrometer

Bruker micrOTOF-Q II Quadrupole.jpg

This instrument is a high-resolution accurate mass quadrupole-time-of-flight mass spectrometer, with electrospray, nanospray, atmospheric-pressure chemical ionization, and atmospheric-pressure photoionization sources with a mass range of 50-3000 m/z, an average resolution (m/Δm, width at 10%) of 8,000, and the capability to perform collision-induced dissociation (CID) tandem mass spectrometry experiments, up to MS2. This instrument is housed in laboratory space permitted to handle low-level uranium-containing radioactive samples. This instrument is connected to a Waters H-Class Plus Ultra High Performance Liquid Chromatorgaph (UHPLC), for chromatographic separation of samples prior to mass analysis. This instrument is primarily used for identification and quantification of organic unknowns, although it can also be used for cluster studies.​​​​

​​

​Bruker amaZon Speed ETD Ion Trap Mass Spectrometer

Bruker amaZon Speed ETD.jpg

This instrument is a quadrupole ion trap mass spectrometer, with electrospray, nanospray, atmospheric-pressure chemical ionization, and atmospheric-pressure photoionization sources with a mass range of 25-3000 m/z and the capability to perform collision-induced dissociation, electron-transfer dissociation (ETD), and proton-reaction dissociation (PRD) tandem mass spectrometry experiments, up to MS9. This instrument is housed in laboratory space permitted to handle low-level uranium-containing radioactive samples. This instrument can be connected to a Thermo Dionex Ultimate 3000 Ultra High Performance Liquid Chromatorgaph (UHPLC), for chromatographic separation of samples prior to mass analysis. This instrument is primarily used for metal ligand cluster fragmentation studies, although it can also be used for identification and quantification of unknowns.



​​Thermo LCQ Deca XP Max Ion Trap Mass Spectrometer

​This instrument is a quadrupole ion-trap with electrospray and nanospray ionization sources, with a mass range of 15-1200 m/z and the capability to perform collision-induced dissociation tandem mass spectrometry experiments up to MS10. This instrument is located in a Contamination Area, permitted to handle high-activity radioactive samples. This instrument is primarily used for metal ligand cluster fragmentation studies, although it can also be used for identification and quantification of unknowns.



​Thermo LCQ Deca XP Plus Ion Trap Mass Spectrometer

This instrument is a quadrupole ion-trap with electrospray and nanospray ionization sources, with a mass range of 15-1200 m/z and the capability to perform collision-induced dissociation tandem mass spectrometry experiments up to MS10. This instrument is housed in laboratory space permitted to handle low-level and sealed radioactive samples. This instrument is primarily used for metal ligand cluster fragmentation studies, although it can also be used for identification and quantification of unknowns.​


LECO Pegasus 4D 2-Dimensional Gas Chromatography Time-of-Flight Mass Spectrometer

LECO Pegasus 4D.jpg

​​​​This instrument is a two-dimensional gas chromatograph with a time-of-flight mass spectrometer detector.The mass spectrometer has an electron impact ionization source, unit mass resolution, and a mass range of 10-1000 m/z. This instrument can be equipped with a CDS Analytical pyrolyzer for analysis of solids. This instrument is excellent for identifying organic components in very complex mixtures, and is adequate for quantification.​






​​Other Gas-Chromatography Instruments​

​The facility has several single dimension gas chromatographs with mass spectrometry detectors. Most have single quadrupole mass analyzers with electron impact ionization, but one has a triple-quadrupole mass analyzer with electron impact, and positive and negative chemical ionization sources. The facility also has numerous gas chromatographs with flame ionization, barrier ionization, electron capture, flame photometric, nitrogen-phosphorous, and thermal conductivity detectors. Most instruments are configured for liquid analysis, though some are dedicated for gas and non-condensable analysis. These instruments are used for characterization of organic unknowns, and quantific​​ation measurements.​​​​​

Other Gas-Chromatography Instruments 1.jpg   Other Gas-Chromatography Instruments 2.jpg